Thank you for choosing our Spiral High Speed Door.

In order to facilitate your use, please read this product manual carefully before carrying out related operations.

This manual mainly provides relevant guidance and instructions for users to use and maintain correctly. The manual includes parameter setting, abnormal diagnosis, exclusion and routine maintenance of the controller.

Our company keep any appropriate technology, to improve the production and commercialization  modified rights, at the same time, the basic characteristics of the product does not change.

Special notes:

Ø Before wiring, please confirm that the input power has been cut off, and it is forbidden to plug the aviation plug.

Ø Please confirm whether the power voltage of the main circuit is consistent with the rated voltage of the controller, and ensure the grounding terminal is reliable.

Ø Do not touch the output terminals directly. Do not connect the output terminals short or with the shell.

Ø After cutting off the ac power, the LCD is not extinguished, said controller inside still has high pressure, do not touch the internal circuit and electronic components.

Ø The electronic components inside the controller are particularly sensitive to static electricity, so you must not place foreign matter into the motor drive or touch the main circuit board.

Ø Install any part, must power off and wait for the LED lights on the circuit board out!Do not Hot-line Work!

Ø Do not wet hands, please wear insulated gloves! Do not touch the components and solder joints outside the key insulation!



Spiral High Speed Door- A new metal industrial door that combines heat preservation, energy saving, sealing, high efficiency, wind resistance and environmental protection, opening speed up to 2.5 meters per second,suitable for logistics channels that require frequent high speed.

The door panel is 0.7mm aluminum alloy with insolation PU foam inside.

Every panel is 40mm thickness, 180mm width, 1.36kg per meter.With good insulation, light weight, high strength, impact resistance and other characteristics, wind resistance level ≤ 12 and anti-theft.This type of door is suitable for the rapid passage of indoor and outdoor logistics and production. This type of door can save a lot of energy loss caused by air circulation for the enterprise, and saves about 90% of energy compared to ordinary industrial sliding doors and rolling shutter doors.The rapid opening and closing of this type of door has greatly improved the speed of transportation of production and logistics in the enterprise.The door is the only channel for the company's logistics and production. Its use and selection directly affect the efficiency of the company's production and logistics.This product has high reliability, practicality, easy operation and quick repair.The drive control adopts a stable, energy-saving, and accurate hard door system to ensure the reliable operation of the door and ensure that the annual trouble-free operation reaches more than 300,000 times.




Application and maintenance

1. Before usage, it is necessary to check the power supply, voltage and phase match the speed of the turbo fast door, and ensure the correct direction of operation of the fast door.

2. Wire connection in the open Control Box, inspection and maintenance can only be carried out in the situation of disconnected power, in particular to comply with the precautions in the warning.

3. Adjust the detection range of radar or geomagnetic appropriately.

4. When there is a power outage, the emergency stop switch should be pressed to avoid door go down abruptly and make any hurt.

5. When installing, debugging/opening or closing the door, it is forbidden to walk or standing under the door;

6. Periodically (1 month) Wipe the infrared switch with a clean cloth to ensure the regular use of this function.

7. Regularly (1 month) wipe the door panel with a clean cloth to keep the door clean.

8. Clean the panel of the door (steel structure) with a clean cloth every 1-2 months so that the fast door is still bright as new.

9.Regular (6 months) check the screws of the control box and the inner box, to check whether the wire and power cord have aging.

10. Regularly (3 months) add lubricant to reducer and replace oil.

11. After take use of manual operation when the power outage, the door must be positioned at the bottom, otherwise the fast door can not operate normally.

12. When the power is cut off, the electronic control system can manually open the motor brake. The door body can be lifted by means of the balancing system.

13. The damage caused by the operation of the control cabinet without the authorization from the seller or service company. We shall not bear the responsibility for free maintenance.